Electrosurgical Unit
With the advent of state-of-the-art technology, the electroscalpel has made surgery a safer and more efficient experience; the increasingly common use of these devices has raised some concerns about the safe and proper use of them.
To promote the safe use of electroscalpel, several regulations have been put in place to ensure the safety of patients and health personnel; first, the electroscalpel must be identified by the laboratory’s clinical experts before use, receiving their respective inspection and review.
Types of Electrosurgical Unit that may be needed in a Medical Sector
Electrosurgical Generators YR02145
YR electrosurgical series generator is a versatile electrosurgical unit for all around surgical procedures through all types of tissue...
Electrosurgical Generators YR02147
YR electrosurgical generator series is a reliable electrosurgical unit for loop electrosurgical excision procedure (LEEP)...
Electrosurgical Generators YR02144
Electrosurgical generator combines versatility and safety, for all general electrosurgical procedures such as cutting and...
Our best-selling Electrosurgical Unit
- 7 monopolar and 3 bipolar outputs are available.
- The electrosurgical generator ensures smooth cutting through all types of tissue.
- It realizes automatic recognition of return electrode, whether solid or spilt.
- It offers automatic current monitoring and program memory functions.
- The argon module is optional for enhanced cutting and coagulation.
- Optional adaptor for laparoscopy and thoracoscopy application.
- The electrosurgical generator has an easy to use interface.
- It features isolated output, all floating.
Model | YR02144 | |||
Monopolar | ||||
Cutting mode | Max. Output power (watts) | Load (ohms) | Open circuit Vp-p | Crest factor |
Pure | 400 watts | 500 Ω | 2,300v | Sun May 01 2022 00:00:00 GMT + 0200 (Central European Summer Time) |
Mix 1 | 300 watts | 500 Ω | 2,700v | Sun Jan 02 2022 00:00:00 GMT + 0100 (Central European Standard Time) |
Mix 2 | 200 watts | 500 Ω | 3,200v | Mon May 02 2022 00:00:00 GMT + 0200 (Central European Summer Time) |
Mix 3 | 150 watts | 500 Ω | 3,700 v | Mon Jan 03 2022 00:00:00 GMT + 0100 (Central European Standard Time) |
Coagulation mode | ||||
Point | 120 watts | 500 Ω | 5,600v | Thu Jan 06 2022 00:00:00 GMT + 0100 (Central European Standard Time) |
Gentle | 120 watts | 500 Ω | 3,400 v | Thu Jan 06 2022 00:00:00 GMT + 0100 (Central European Standard Time) |
Spray | 120 watts | 500 Ω | 8,500 v | Tue Mar 08 2022 00:00:00 GMT + 0100 (Central European Standard Time) |
Bipolar | ||||
Cutting mode | ||||
Standard | 70 watts | 200 Ω | 1,450v | Sun May 01 2022 00:00:00 GMT + 0200 (Central European Summer Time) |
Coagulation mode | ||||
Standard | 70 watts | 500 Ω | 240v | Sun May 01 2022 00:00:00 GMT + 0200 (Central European Summer Time) |
Precise | 70 watts | 200 Ω | 360v | Sun May 01 2022 00:00:00 GMT + 0200 (Central European Summer Time) |
Connecting accessories and supplies | ||||
Finger pencil | two | |||
Foot switch pencil | one | |||
Patient return electrode | one | |||
Foot switch | one | |||
Ac power supply | one | |||
Potential equalization | one | |||
Power characteristic | ||||
Rate frequency | 512 kHz (110 / 240vAC, 60 / 50Hz) | |||
Isolated output | YES | |||
Quantitative visualization of the contact area | YES, for the «Split» type of neutral electrode | |||
Contact area indicator lamp | 10 lamps (one for 10% contact), alarm beep and flash if contact <20% | |||
Definition of Solid / Split Neutral Electrode | YES, the ‘Split’ or ‘Solid’ indicator light comes on | |||
Adjustable alarm volume | YES | |||
Operating duty cycle | 10 seconds ON, 30 seconds OFF | |||
Cooling method | Convection | |||
Regulation | ||||
Type According to EN 60601-1 | CF | |||
Protection class according to EN 60601-1 | class I | |||
Classification acc. According to MDD 93/42 / EEC | IIb | |||
Physical | ||||
Dimension (WxDxH) | 460 x 410 x 160 mm | |||
Weight | 11.2 kg |
Guides for you to become an expert in Electrosurgical Unit
Burns or Electroscalpel-related adverse events
Electrosurgery is an operation that is currently very common, and like any surgery, requires some steps or...
What is the importance of an Electroscalpel?
An electroscalpel is a medical equipment capable of transforming electrical energy into heat with the aim of...
Electrosurgery, what is it and how does it work?
The electrosurgery unit, or electrosurgery, is a medical device that uses electrical phenomena to produce heat...
What is the electric clotting scalpel?
An electric coagulation scalpel is a medical and electronic device that converts electrical energy into heat to coagulate tissues and cauterize them simultaneously, using currents with frequencies above 200,000...
Frequently asked questions from our customers about Electrosurgical Units
How to know the prices of the Electrosurgical Units?
To know the price of the Electrosurgical Units we invite you to send us an e-mail with your request through the contact form.
What are the delivery times for Electrosurgical Units?
- If the equipment of your interest is in stock or if it must be manufactured.
- The type of freight you have chosen, this may be; air or sea.
How to purchase Electrosurgical Units?
- By email: [email protected]
- By telephone: +33 (0) 1 78 95 87 02
- E-commerce: Via Kalstein's official website in your country.
How does the warranty work?
Can I request a quote online?
Of course, you can request a quote for the Kalstein team of your interest, directly from our official website. Once you have identified your preferred model, click HERE